YLJ-50 Steel Bar Prestressed Tensile Machine
Short Description:
It is the first choice to achieve strict quality control of rebar thread bars. This machine is suitable for rebars with a nominal diameter of 16mm~50mm. This machine uses static force to load the thread bar of rebars and maintain it for a period of time to perform load testing on the thread bars and eliminate the residual stress of the thread bars. Features ●The main body of this machine adopts an integrated frame, and the structure is stable and reliable; ●Separate hydraulic station, easy ma...
It is the first choice to achieve strict quality control of rebar thread bars. This machine is suitable for rebars with a nominal diameter of 16mm~50mm. This machine uses static force to load the thread bar of rebars and maintain it for a period of time to perform load testing on the thread bars and eliminate the residual stress of the thread bars.
Features
●The main body of this machine adopts an integrated frame, and the structure is stable and reliable;
●Separate hydraulic station, easy maintenance;
●PLC with touch screen control method, visual operation, mature and stable;
●The rebars are clamped using upper and lower cylinders for top clamping. The clamp adopts a V-shaped structure and is compatible with a variety of specifications. The structure is stable and the changeover time is short;
●Tensile force is collected through high-precision sensors, which can achieve precise control of prestress.
YLJ-50 Main Technical Parameters |
|||
Main Machine Dimensions | 1300mm×900mm×1700mm | Capacity | 160L |
Hydraulic Control Cabint Size | 1100mm×560mm×1000mm | Clamping Cylinder Stroke | 50mm |
Main Machine Weight | 1700kg | Clamping Cylinder Nominal Pressure | 31.5MPa |
Hydraulic Control Cabinet Weight | 3200kg | Clamping Cylinder Max. Working Pressure | 28MPa |
Rebar Processing Range | 16mm-50mm | Pre-tension Cylinder stroke | 30mm |
High-pressure Hydraulic Pump Motor | 2.2kW | Nominal Pressure Of Clamping Cylinder | 31.5MPa |
Low-pressure Hydraulic Pump Motor | 3.7kW | Max. Working Pressure Of Pre-tension Cylinder | 25MPa |
Environment Temperature | -5℃-50℃ | Installation Location | Interior |
Control Program | PLC with touch screen | Input Power | 380V 3P 50Hz |