Factory supplied Duct Canvas Connector From China - ACJ Standard coupler – YIDA

Short Description:

Hebei Yida Reinforcing Bar Connecting Technology Co.,Ltd Anti Impact Rebar Coupling System  1.Hebei Yida Anti Impact Rebar Coupling system is divided into the following types: (1)ACJ Standard Coupler 2.1 (2)BCJ Transition Coupler 2.2 (3)FCJ Positive and negative Thread Coupler 2.3 (4)KCJ Adjustable Coupler 2.4 (5)MCJ Anchorage Terminator Coupler 2.5 2. Introduction Hebei Yida Anti Impact Rebar Coupling system is a mechanical rebar splicing system, be made of high quality alloy ...


Product Detail

Product Tags

Related Video

Feedback (2)

We've got a highly efficient group to deal with inquiries from shoppers. Our purpose is "100% client fulfillment by our product high-quality, price tag & our staff service" and enjoy a superb reputation amongst clientele. With quite a few factories, we will provide a wide variety of Rebar Sleeve Joint , Manual Thread Cutting , FCJ Positive and negative Thread Coupler , We have four leading products. Our products are best sold not only in the Chinese market, but also welcomed in the international market.
Factory supplied Duct Canvas Connector From China - ACJ Standard coupler – YIDA Detail:

Hebei Yida Reinforcing Bar Connecting Technology Co.,Ltd

Anti Impact Rebar Coupling System 

1.Hebei Yida Anti Impact Rebar Coupling system is divided into the following types

(1)ACJ Standard Coupler 2.1

(2)BCJ Transition Coupler 2.2

(3)FCJ Positive and negative Thread Coupler 2.3

(4)KCJ Adjustable Coupler 2.4

(5)MCJ Anchorage Terminator Coupler 2.5

2. Introduction

Hebei Yida Anti Impact Rebar Coupling system is a mechanical rebar splicing system, be made of high quality alloy steel. It has already passed the High Speed Tensile test of Anti instant impact by Germany Berlin BAM Laboratory. It has been widely applied at the sites where required high level of resistance to impact. The coupler sleeve will be perfect connected with rebar by cold swaged deformation in the application, and dual couplers will be connected by a high strength bolt.

Special Advantages:

(1)Each rebar is connected by cold swaged with a coupling, It was processed by large-tonnage hydraulic machine and unique split mould to ensure high quality and reliable radial deformation swage. Connection of rebar with coupler after swaged as shown in Figure 1.

 1

Figure 1

(2)Rebar sleeve bond press is done prior to site connection saving precious site time.

(3)The two sleeves are connected through a high-strength bolt, quality ensured.

(4)Installation on site is easy and fast, even in dense cages. No X-ray check is needed and installation can be done in any weather conditions.

(5)No thread cutting, no need heat or pre-heat on rebar, hence the rebar retains its original characteristics after splice.

(6)The Yida ACJ rebar coupling system stands complex or full tension as well as full compression state.

 

2.1ACJ Standard Coupler

ACJ standard coupler is made up by two standard sleeves and one standard bolt (as shown in Figure 2), suitable for same diameter rebar connecting. The Yida ACJ is suitable for general application such as beams or walls where the rotation

of the rebar is possible. Screw the bolt into one sleeve firstly, then rotate one rebar to screw the other bolt end into the other sleeve.

 2

Figure 2

Characteristic:ACJ coupler uses standard female (sleeve) only, making rebar press more efficient as there is no need to specify different sleeves.

Application Guide:

Proper installation is very important to ensure the design load will be reached in the application. Yida strongly recommends that the installation and site quality check be done according to the required guidelines and dimensions.

  • Rebar And sleeves swaged connection

Using hydraulic machine and unique split mould to swage sleeve deformation, formed the seamless connection with rebar and the swage length is to meet the standard swage length. Shorter swage length reduces the bond, while longer swage length may shorten the engagement length of the thread.

  • Site installation method

Step 1:Screw the bolt into female coupler swaged with rebar, till unable to screw continually. As shown in Figure 3.

 3

Figure 3

Step 2:Screw another side of bolt into the other sleeve after swaged with rebar, till unable to screw continually. As shown in Figure 4. 

 4

Figure 4

Step 3:With help of two pipe wrench, tighten the connection by turning both rebar / couplers in opposite direction at the same time. 

 


Product detail pictures:

Factory supplied Duct Canvas Connector From China - ACJ Standard coupler – YIDA detail pictures

Factory supplied Duct Canvas Connector From China - ACJ Standard coupler – YIDA detail pictures

Factory supplied Duct Canvas Connector From China - ACJ Standard coupler – YIDA detail pictures


Related Product Guide:
How to Save Time and Cost With a 316 Stainless Steel Bar
Steel Square Bars For Your Roof

We pursue the management tenet of "Quality is superior, Service is supreme, Reputation is first", and will sincerely create and share success with all clients for Factory supplied Duct Canvas Connector From China - ACJ Standard coupler – YIDA, The product will supply to all over the world, such as: London, Amsterdam, Uzbekistan, We have to continue to uphold the "quality, comprehensive, efficient" business philosophy of "honest, responsible, innovative"spirit of service, abide by the contract and abide by reputation, first-class products and improve service welcome overseas customers patrons.
  • The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
    5 Stars By Sandra from Malaysia - 2016.10.25 15:53
    We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
    5 Stars By Louise from Chile - 2015.02.08 16:45

    Related Products

    WhatsApp Online Chat !